UNIVERSAL PIERCING SYSTEM


>OPERATING INSTRUCTIONS

   

Loading the Instrument
1. Cock the instrument by drawing the plunger back until it locks into place.
2. Grasp blister backing paper and peel away to expose the sterilized rigid plastic mount that holds the studs and clasps. BE SURE NOT TO TOUCH THE STUDS once the package is opened or the sterilization will be lost (Figures 6-1 & 6-2).




3. Being careful not to touch the studs, flip the plastic mount up with the index finger enough to grasp the sides of the mount with the thumb and middle finger (Figures 7-1 & 7-2). Lift the mount out of the sterile container.




The studs should be at the bottom of the mount and the clasps at the top of the mount (Figure 7-3).

4. Insert one stud head into the stud adapter and pull the mount straight up to release the stud from the mount (Figure 8).



5. While keeping the instrument in the upright position, slide the corresponding clasp (located directly above the stud) into the clasp retainer at the end of the instrument (Figure 9).




   

 